XKE-124 T-bar Calibration Utility

1. Plug in one XKE-124 T-bar unit.
2. Start TbarCalibrationUtility.exe. Note PIEHid32Net.dll must be in the same directory as the .exe and both must be copied to the local machine you are plugging in the XKE-124 to.
3. Click Enumerate.
4. Click Start Cal and slowly move the T-bar up and down throughout its full range. Slowly is about 5 seconds for the full range. Do this 2 times to be sure the limits are hit. It can be done more than 2 times if one feels they may have gone too fast.
5. Click Stop Cal.